CALL0203 008 5940     Facebook     Twitter     Linkedin

Air to Water Chillers

Machines for the production of chilled water or, in heat pump versions, hot water. The cold water produced will serve for air conditioning of the room or for taking out the heat developed in various industrial processes. The machines are intended for installation outdoors and are air-cooled.

CWX

Refrigerant: R410A
Cooling capacity: from 3500 to 6700 W

Low chiller range split unit with water-cooled condensation.
Data Sheet

FW-R

Refrigerant: R407C
Cooling capacity: from 3000 to 4500 W

Low chiller range monobloc unit with water-cooled condensation.
Data Sheet

ANL 020 ÷ 202

Refrigerant: R410A
Cooling capacity: from 5,7 to 43 kW

Low chiller range with axial fans, Scroll compressors and plate type exchangers. Also available in versions with storage tank and circulation pump.

Data Sheet

ANL 290 ÷ 650

Refrigerant: R410A
Cooling capacity: from 54,5 to 132,9 kW

Medium chiller range with axial fans, Scroll compressors and plate type exchangers. Also available in versions with storage tank and circulation pump.

ANL Data Sheet

ANLI

Refrigerant: R410A
Cooling capacity: from 5,88 to 28,77 kW

Low power heat pumps with axial fans, Inverter Scroll compressors and plate type exchangers. Also available in versions with circulation pump.

Data Sheet

ANK

Refrigerant: R410A
Cooling capacity: from 6,76 to 15,48 kW

Low power heat pumps with axial fans, Scroll compressors
and plate type exchangers. Also available in versions
with circulation pump.

Data Sheet

CL

Refrigerant: R410A
Cooling capacity: from 5,5 to 39,3 kW

Low power chillers with centrifugal fans, Scroll compressors and plate type exchangers. Also available in versions with circulation pump or with storage tank and circulation pump.

Data Sheet

NRB

Refrigerant: R410A
Cooling capacity: from 217 to 1047 kW

Chiller with axial fans, Scroll compressors, plate type exchangers and micro-channel air exchangers. Also available in versions with storage tank and circulation pump.
NRB Data Sheet

NRL

Refrigerant: R410A
Cooling capacity: from 53 to 953 kW

Chiller with axial fans, Scroll compressors and plate type exchangers. Also available in versions with storage tank and circulation pump.

NRL-1co Data Sheet

NRL-1fc Data Sheet

NRL-2co Data Sheet

NRL-2fc Data Sheet

NRL-3co Data Sheet

NRL-3fc Data Sheet

NRL Brochure

NRK

Refrigerant: R410A
Cooling capacity: from 36,00 to 148,00 kW

Units optimized for heating operation.
Medium power chillers with axial fans, Scroll compressors and plate type exchangers.
Also available in versions with storage tank and circulation pump.

Data Sheet

NRC

Refrigerant: R407C
Cooling capacity: from 46 to 264 kW

Medium chiller range with radial fans, Scroll compressors and plate type exchangers. Also available in versions with circulation pump or with storage tank and circulation pump.

Data Sheet

NSM

Refrigerant: R134a
Cooling capacity: from 302,00 to 2.100,00 kW

High chiller range with axial fans, twin-screw compressors, tube core water exchangers and micro-channel air exchangers.

Data Sheet

NS

Refrigerant: R134a
Cooling capacity: from 238 to 1600 kW

High chiller range with axial fans, twin-screw compressors and tube core exchangers.

NS co Data Sheet

NS fc Data Sheet

NS fc hwt Data Sheet

NS fc gf Data Sheet

NS fc hwt Data Sheet

NSI

Refrigerant: R134a
Cooling capacity: from 262 to 1249 kW

High chiller range with axial fans, compressors with magnetic levitation bearings and tube core exchangers.

NSI co Data Sheet

NSI fc Data Sheet

TBX

Refrigerant: R134a
Cooling capacity: from 259 to 861 kW

High chiller range with axial fans, compressors with magnetic levitation bearings and tube core exchangers.
Data Sheet